Thank you for your interest in the Transformer Power NSN parts we have available for purchase on NSN Parts World. On this page, you can submit a quote request for Ametek Programmable Power Inc part number HIT-5.0-13, a component that can also be found by inputting NSN 5950013317786 in our search engine. Other than this particular part number, we also carry an array of other high-quality items that have been sourced from leading global entities on our Approved Vendor List (AVL). Explore our vast catalogs by scrolling over to our menu and find products according to manufacturer, NIIN, NSN, and more.
Note : We Will Not Share Your Information To Any Third Parties.
At NSN Parts World, we work with a number of government and defense agencies, meaning that you can find items by their respective CAGE Codes, including 25965, and many others. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Ametek Programmable Power Inc parts under the FSC 5950 Coils and Transformers. As such, we invite you to confidently complete the RFQ form for NSN 5950013317786 or any other, and within 15 minutes or less of submission, one of our experts will reach out with a customized solution. For one-on-one assistance, contact via phone or email; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-331-7786 Item PartTypeName: TRANSFORMER,POWER | 5950 | 013317786 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
HIT-5.0-13 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT AND HUMIDITY RESISTANT |
ABHP | OVERALL LENGTH | 15.250 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 6.880 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.440 INCHES NOMINAL SINGLE GROUP |
ACZF | MAXIMUM TRANSFORMER POWER RATING | 5.0 KILOVOLT-AMPERE SINGLE COMPONENT |
AEHZ | MAXIMUM OPERATING TEMP | 130.0 DEG CELSIUS |
TEST | TEST DATA DOCUMENT | 30003-1217AS310 DRAWING (THIS IS THE BASIC GOVERNING DRAWING,SUCH AS A CONTRACTOR DRAWING,ORIGINAL EQUIPMENT MANUFACTURER DRAWING,ETC.; EXCLUDES ANY SPECIFICATION,STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DR |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 8.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 7.250 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 8.630 INCHES MAXIMUM |
ACZB | FREQUENCY RATING | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
AKPV | MOUNTING FACILITY QUANTITY | 4 SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 2 PRIMARY SINGLE COMPONENT AND 2 SECONDARY SINGLE COMPONENT |
CRBZ | WINDING OPERATING CURRENT | 41.0 AMPERES AC MAXIMUM SINGLE COMPONENT ALL SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL SECONDARY |
ACZX | WINDING SHIELDING METHOD | PRIMARY AND SECONDARY SHIELDED AND BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | SLOT SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 120.00 AC VOLTS NOMINAL SINGLE COMPONENT ALL PRIMARY |