Thank you for your interest in the Transformer Power NSN parts we have available for purchase on NSN Parts World. On this page, you can submit a quote request for Ballastran Corp part number 5059, a component that can also be found by inputting NSN 5950001184007 in our search engine. Other than this particular part number, we also carry an array of other high-quality items that have been sourced from leading global entities on our Approved Vendor List (AVL). Explore our vast catalogs by scrolling over to our menu and find products according to manufacturer, NIIN, NSN, and more.
Note : We Will Not Share Your Information To Any Third Parties.
At NSN Parts World, we work with a number of government and defense agencies, meaning that you can find items by their respective CAGE Codes, including 97315, and many others. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Ballastran Corp parts under the FSC 5950 Coils and Transformers. As such, we invite you to confidently complete the RFQ form for NSN 5950001184007 or any other, and within 15 minutes or less of submission, one of our experts will reach out with a customized solution. For one-on-one assistance, contact via phone or email; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-00-118-4007 Item Description: TRANSFORMER,POWER | 5950 | 001184007 | P | |||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
5059 | 6 | 2 | 1 |
MRC | Criteria | Characteristic |
---|---|---|
AKPV | Mounting Facility Quantity | 2 SINGLE GROUP |
TTQY | Terminal Type And Quantity | 9 SOLDER STUD |
CWJS | Winding Operating Voltage | 100.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY |
CWJS | Winding Operating Voltage | 185.00 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY |
CWJS | Winding Operating Voltage | 5.50 AC POUNDS PER HOUR WET SINGLE COMPONENT 2ND SECONDARY |
ADAU | Body Height | 0.187 INCHES NOMINAL |
AXGY | Mounting Method | UNTHREADED HOLE SINGLE GROUP |
AKNA | Inclosure Type | FULLY INCLOSED |
CRBZ | Winding Operating Current | 20.0 MILLIAMPERES AC MAXIMUM SINGLE COMPONENT 3RD SECONDARY |
CRBZ | Winding Operating Current | 4.0 AMPERES AC MAXIMUM SINGLE COMPONENT 1ST SECONDARY |
CRBZ | Winding Operating Current | 3.0 AMPERES AC MAXIMUM SINGLE COMPONENT 2ND SECONDARY |
ACZC | Input-Output Phase Relationship | SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT |
ACZX | Winding Shielding Method | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ACZB | Frequency Rating | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ADAQ | Body Length | 0.250 INCHES NOMINAL |
AEJN | Distance Between Mounting Facility Centers | 1.700 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
BPLC | Winding Function And Quantity | 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT |
CWJS | Winding Operating Voltage | 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY |
ABTB | Mounting Hole Diameter | 0.214 INCHES NOMINAL SINGLE GROUP |
MRC | Decoded Requirement | Clear Text Reply |
ADAT | Body Width | 0.250 INCHES NOMINAL |