Thank you for your interest in the Circuit Breaker NSN parts we have available for purchase on NSN Parts World. On this page, you can submit a quote request for Ge Industrial Systems Solutions Inc part number TEY240, a component that can also be found by inputting NSN 5925015394044 in our search engine. Other than this particular part number, we also carry an array of other high-quality items that have been sourced from leading global entities on our Approved Vendor List (AVL). Explore our vast catalogs by scrolling over to our menu and find products according to manufacturer, NIIN, NSN, and more.
Note : We Will Not Share Your Information To Any Third Parties.
At NSN Parts World, we work with a number of government and defense agencies, meaning that you can find items by their respective CAGE Codes, including 1ZDV7, and many others. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Ge Industrial Systems Solutions Inc parts under the FSC 5925 Circuit Breakers. As such, we invite you to confidently complete the RFQ form for NSN 5925015394044 or any other, and within 15 minutes or less of submission, one of our experts will reach out with a customized solution. For one-on-one assistance, contact via phone or email; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5925-01-539-4044 Item PartTypeName: CIRCUIT BREAKER | 5925 | 015394044 | 0 | P | A | |
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | A | 0 | |||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
TEY240 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AKPX | Pole Quantity | 2 |
CPLM | Maximum Continuous Load Current Rating Per Pole | 40.0 AMPERES AC ALL LOCATIONS |
CPRF | Operating Voltage Type And Rating Per Pole In Volts | 277.0 AC ALL LOCATIONS |
FREQ | Frequency In Hertz | 60.0 ALL LOCATIONS |
CPRH | Circuit Protection Type | OVERCURRENT ALL LOCATIONS |
CPRG | Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps | 14000.0 AC ALL LOCATIONS |
CPRL | Trip Release Characteristic | INSTANTANEOUS ALL LOCATIONS |
CXCY | Part Name Assigned By Controlling Agency | ERS HOSE REEL BASE ASSEMBLY |
CPRN | Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent | 125.0 ALL LOCATIONS |
TTQY | Terminal Type And Quantity | 4 COMPRESSION |
CPRR | Main Contact Tripping Mechanism Type | TRIP FREE |
CPRQ | Reset Method | MANUAL |
CPRW | Actuator Function | TRIP-RESET |
ABHP | Overall Length | 5.250 INCHES NOMINAL |
ADTV | Case Material | PLASTIC |
CPRX | Actuator Position Designation | AT POLE ONE |
AXHR | Mounting Facility Type And Quantity | 4 UNTHREADED HOLE |
CPSM | Internal Trip Release Configuration | SERIES TRIP ALL LOCATIONS |
ABKW | Overall Height | 3.0625 INCHES NOMINAL |
ABMK | Overall Width | 2.000 INCHES NOMINAL |
FEAT | Special Features | MOLDED CASE, THERMAL MAGNETIC |
CPRJ | Trip Release Method | MAGNETIC ALL LOCATIONS |
AAQL | Body Style | RECTANGULAR DIMENSIONAL ENVELOPE |
CPRT | Manual Actuator Type And Quantity | 1 TOGGLE |
MRC | Decoded Requirement | Clear Text Reply |
AEBV | Unthreaded Mounting Hole Diameter | 0.196 INCHES NOMINAL |
AGAV | End Item Identification | ASSUALT HOSELINE SYSTEM (AHS) |