Thank you for your interest in the Transformer Power NSN parts we have available for purchase on NSN Parts World. On this page, you can submit a quote request for Toroid Corp part number 713.1202, a component that can also be found by inputting NSN 6120014699388 in our search engine. Other than this particular part number, we also carry an array of other high-quality items that have been sourced from leading global entities on our Approved Vendor List (AVL). Explore our vast catalogs by scrolling over to our menu and find products according to manufacturer, NIIN, NSN, and more.
Note : We Will Not Share Your Information To Any Third Parties.
At NSN Parts World, we work with a number of government and defense agencies, meaning that you can find items by their respective CAGE Codes, including 0FZR3, and many others. Additionally, we utilize Federal Supply Classes (FSCs) to organize our stock, ensuring customers can find Toroid Corp parts under the FSC 6120 Transformers Distribution and Power Station. As such, we invite you to confidently complete the RFQ form for NSN 6120014699388 or any other, and within 15 minutes or less of submission, one of our experts will reach out with a customized solution. For one-on-one assistance, contact via phone or email; we are available 24/7x365!
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
6120-01-469-9388 Item PartTypeName: TRANSFORMER,POWER | 6120 | 014699388 | N | A | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
A | A | 0 | ||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
CTR015 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABTB | Mounting Hole Diameter | 0.250 INCHES NOMINAL SINGLE GROUP |
CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CBBL | Features Provided | COLOR CODED LEAD AND PROTECTIVE COVER AND SPECIAL MARKING |
ADAU | Body Height | 1.900 INCHES NOMINAL |
ACZB | Frequency Rating | 50.0 HERTZ NOMINAL SINGLE COMPONENT OR 60.0 HERTZ NOMINAL SINGLE COMPONENT |
CRBZ | Winding Operating Current | 0.6 AMPERES AC NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
TTQY | Terminal Type And Quantity | 4 WIRE LEAD |
CRBZ | Winding Operating Current | 0.7 AMPERES AC MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 1.4 AMPERES AC MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
ACZF | Maximum Transformer Power Rating | 150.0 VOLT-AMPERE SINGLE COMPONENT |
AXGY | Mounting Method | UNTHREADED HOLE SINGLE GROUP |
FEAT | Special Features | SUPPLY VOLTAGE RANGE IS PLUS OR MINUS 10 PERCENT; PRIMARIES ARE INSIDE SLEEVE AND MUST BE CONNECTED TOGETHER IN SERIES OR PARALLEL; PRIMARY LEAD WIRES ARE MAGNET WIRE SELF-LEADS, 24 GAUGE, 8.000 IN. LENGTH NOMINAL; SECONDARY LEAD WIRES ARE MULTI-STRANDED, 22 GAUGE, 8.000 IN. LENGTH NOMINAL; CORE NO. 900140, NO-LOAD LOSS EQUALS 0.9 WATT , NO-LOAD AMPERAGE EQUALS 8.7 MILLIAMPS; UL RECOGNIZED TO UL 1411 AND CSA CERTIFIED TO CSA C22.2, NO. 66 |
ADAR | Body Outside Diameter | 3.900 INCHES NOMINAL |
MRC | Decoded Requirement | Clear Text Reply |
AEHZ | Maximum Operating Temp | 65.0 DEG CELSIUS |
CWJS | Winding Operating Voltage | 117.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE SECONDARY |
AARG | Reliability Indicator | NOT ESTABLISHED |
AKNA | Inclosure Type | FULLY INCLOSED |